Waterproof Shed Cheap Plastic Roofing Sheets

Brand: XINGFA

Thickness:1.5mm,2.0mm,2.3mm,2.5m,2.8mm,3.0mm

Width:1130mm

Color: White

Layers: 3 Layers

Supply Type: OEM/ODM

Delivery Time: 10-15 Working days after advance

MOQ: 2000 square meters

Warranty: 10 years

12 People watching this product now!
Description

Waterproof Shed Cheap Plastic Roofing Sheets

XINGFA UPVC Trapezoidal T1130 Specification

Width: 1130mm
Effective Width: 1050mm
Length: Customized
Thickness: 1.5mm,2.0mm,2.3mm,2.5m,2.8mm,3.0mm
Application: Sheds, Workshops, Parking Lots, Production Workshops, Greenhouses, Farms, Chemical Plants, ect.

UPVC Trapezoidal Roof Sheet T1130

Over the past two decades, PVC roof panels have already been utilized in various kinds of business and gardening components around the globe.
From hog barns to dairy food storage sheds or poultry properties, vehicle washes, substance-finalizing plants and flowers, or fertilizer-storing establishments.
Due to its strength and durability, PVC roof panels typically have a long service life. In addition, Corrugated plastic roofing sheets are easy to install using regular resources.

Test Technical Data from SGS
ItemTest MethodTest ConditionResult
Dimensional StabilityASTM D1204-14Specimen: 25cm*25cm
100℃, 60min
Medium: Talc powder
Direction of Vertical-0.60%
Direction of Horizontal1.60%
Vicat Softening temperatureISO 306-2013 method B50Heat-transfer meida: Silicone oil
Rate of temperature: 50K/h
Load: 50N
77.0℃
Fire ratingDIN 4102-1:1998-05Cotton indicator ignited by flaming particles or drops with V-2B2
Effect of liquid chemicalsISO 175-2010Immersion method
Temperature: 23℃
Immersion time: 48h
40%(m/m)NaOHNo visual change
35%(m/m)HCLVisual discoloring, but no other visual change
30%(m/m)H2SO4No visual change
Light Ageing Test
Xenon-arc Exposure
ISO4892-2:2013cycle4
ISO 105-A02:1993/Cor.2:2005
ASTM D2244-15a
Irradiance:(0.51±0.02)W/(m·nm)@340nm
102 min light at (63±3)℃ BPT, (50±10)% RH
18 min light and water spray
Filter: Boro/Boro
Exposure Period: 1000h
Grey Scale: 3
△Eab=1.3
Striker Impacted by a Falling WeightGB/T 8814-2004
Section 5.7
Section 6.7
Condition: -10℃ , 1h →Take out and do the test within 10s
Strik weight:1000g
Height:1000mm
Span:200mm
No. of specimen tested:10
breakage:0
Thermal conductivityASTM C518-17Condition the test specimen at(23+2)°C and(50+5)% relative humidity to constant mass0.09(W/m·K)
Thermal resistance0.03(m2·K)/W
Tensile Breaking strengthGB/T 1040.2-2006Span:115mm
Specimen width: 25mm
Power: 1050N
20.3Mpa
Tensile StrengthGB/T 1040.2-2006Span:115mm
Specimen width: 25mm
Power: 1050N
20.63Mpa